One is called the n2 bus or bus 91 the term bus 91 is not used in north america and is used to interface to a supervisory unit. This manual assumes that the reader is familiar with the dx controllers. The gx tool is part of the mtool suite of programming tools. However, i can honestly say that the dx9100 is a very reliable piece of equipment. This building has a jci ncm350 connecting about 25 different devices via n2. Old metasys system dx9100 questions im in the process of migrating an old jci metasys system with dx9100s and we just moved a dx9100 off the old network to a new networkrockwell system. Email us for a quotemetasys dx 9100 8454 cpu processor controllerthe dx 9100 extended digital controller is the ideal digital control solution for multiple chiller or boiler plant applications, air handling units, or distributed lighting control.
Xt9100 min ao7 ao8 min dx9100 dx9100 xt xp xtm 905 xp xp n2 bus xt bus dx9100xp. Metasys ventilation controller application for the dx 9100 7 dx 9100 the dx 9100 is a controller manufactured and marketed by johnson controls. The gx9100 graphic configuration software tool gx tool is used to configure the dx series of extended digital plant controllers, the xt9100 and xtm905 extension modules, and the dx liquid crystal display lcd display unit. The dx9100 is the ideal digital control solution for multiple chiller or. All of the variations of the n2 protocol will coexist on the same wire and all generations of metasys supervisory controllers can talk to. Smart application to control all the integrated devices in johnson controls or 3rd party bms systems, using a new user experience. Dx9100 extended digital controller series such as the dx91008454 is the ideal digital control solution for multiple chiller or boiler plant applications, air handling units, or distributed lighting control.
Multistory building smoke control with fscs overridemetasys. Streamlined workflows and reduced mouse clicks to boost productivity. Metasys ventilation controller application for the dx9100. Ppt the dx 9100 powerpoint presentation, free download id. S4 metasys configuration file conversion utility the s4.
Gx9100 configuring the dx9100 controller, the xt9100 and xtm905 extension modules, and the dx lcd display. All content is posted anonymously by employees working at metasys technologies. Email us for a quotemetasys dx91008454 cpu processor controllerthe dx9100 extended digital controller is the ideal digital control solution for multiple chiller or boiler plant applications, air handling units, or distributed lighting control. Dx9100 hardware the mvc20001 product utilizes one dx9100. System configuration tool help brand metasys prodname system configuration tool version. Johnson controls metasys dx lcd display digital controllers. Metasys ventilation controller application for the dx9100 dx9100 the dx9100 is a controller manufactured and marketed by johnson controls. Free metasys launcher update download software at updatestar epic games launcher is a desktop tool that allows you to buy and download games and other products from epic games. Johnson controls dx91008454 metasys controller new for sale online. Adding analog output on dx 9100 using gx software youtube. The metasys integrator system includes an extensive series of software drivers for the integration of other manufacturers control devices including hvac equipment, power monitoring devices, lighting panels, card access, security.
Dx91008454 or fadx91008454 version 2 dx912x8454 version 3 with mounting base the dx9100 processes the analog and digital input signals it receives, using 12 multipurpose programmable function modules, a software. The trw supply online store supplies new and refurbished johnson controls metasys dx lcd display and lonworks digital controllers. The smoke control strategy is achieved with the dx9100 dx application and the smoke control network automation engine nae application described in this document, with manual override of the smoke control logic provided by the. Dx 9100 8454 or fadx91008454 version 2 dx 912x8454 version 3 with mounting base the dx 9100 processes the analog and digital input signals it receives, using 12 multipurpose programmable function modules, a software. Dx9100 johnson controls controller dx9100 is available, call trw supply 18004798084 or email to get a quote. Retirement has unofficially arrived but we are always busy on some project. Schedule an appointment with your johnson controls representative to upgrade to metasys. S4 metasys configuration file conversion utility the s4 group. Ppt the dx9100 powerpoint presentation, free download id. Metasys system 91 devices dx9100 metasys variable air volume modular. They use windows 95 and an ancient version of metasys that is 100% text based and blue and yellow in color scheme. Gx9100 software configuration tool users guide, metctw05, or fans 636.
Johnson controls dx91008454 metasys extended digital. View and download metasys dt 9100 8104 installation manual online. Access to the legacy metasys operator workstationa usb thumb drive or other storage mediumthe files can usually be found in the following directories. Johnson controls dx9100 controller facilitator fadx91008454. Technical bulletindx9100 extended digital controller 5 the dx9100 unit versions 1 and 2 has two communication links. Johnson controls dx9100 controller facilitator fadx9100. This feature may include control performance indication, energy consumption, and system. The schedule widget allows authorized users to get the big picture schedule overview by allowing them to view all schedules affecting a space or piece of equipment.
Metasys applicationspecific controller asc devices air handling unit ahu, unitary unt, and variable air volume vav metasys system 91 devices dx9100 metasys variable air volume modular assembly vma1400 xtm105 extension modules thirdparty devices supporting n2 open protocol vnd. This unit does have a long crack in casing on side but will not in anyway effect performance. The missing link is a third party real time computer interface software package. The item tag names shown are the items for which the dx is configured to store trend data. After over 30 years in the industry, we finally decided to reduce our daily involvement with clients. Their system works fine, but its 2016 and they want niagara. I havent encountered any control situation that i cant handle with a dx 9100. All of the variations of the n2 protocol will coexist on the same wire and all generations of metasys supervisory controllers can talk to all n2 devices. Configuration guidesdx9100 configuration guide 9 refer to table 1 for additional information on system 9100 controllers. But if in case saturday or sunday is working they are not paid except lunch or dinner if you have to stay for longer period in office. This is why we have a number of repair options to suit your requirements. Dx9100 series extended digital controller catalog page. Tcdthe tc9100 download file created during the filesavesave as process for a tc9100 configuration, metasys release 9. Metasys building automation and controls field device gx9100 09 gx9100 software configuration tool user guide.
Download metasys looking glass and enjoy it on your iphone, ipad, and ipod touch. The controller is very flexible, especially in applications were a large control panels are not necessary and small application specific. Optimized for mobility, the systems easytouse interface employs new photorealistic graphics for better visualization and faster troubleshooting from. Metasys software it services, consulting and business. Manuals, cables, power cords, software, drivers, accessories, etc are not included unless pictured or noted in the description. As a standalone controller, the dx9100 provides a realtime clock, extendable io, and graphic software programming to target a variety. Johnson controls metasys dx9100 controller dx91008454 used but in great shape you are bidding on a johnson controls dx9100 digital controller note. Includes gx 9100 configuring and commissioning utilities for the dx 9100. The specific system names are used when referring to systemspecific applications. Metasys dt91008104 installation manual pdf download. Hvac pro creates this file after saving a configuration. The time to complete a metasys integration is significantly improved vs.
These utilities are available as part of the mtools package through authorized metasys distributors. Were getting alarms for the removed device, and im not sure how to remove the device from metasys to stop scanning those alarms. Whole foods market americas healthiest grocery store. Controller uses 24v power source with a n2 mstp communication bus. Metasys building automation and controls field device. There are frequent discussions about acquiring, installing, and working with these utilities on the hvac talk forum. Bacnet metasys fecs field equipment controllers johnson.
Gx9100 graphic configuration software gx tool configures the dx series of extended digital plant controllers, the xt9100 and xtm905 extension modules, and the dt9100 dx liquid crystal display lcd. It is designed for installation inside a control panel or on the controlled equipment via din rail. Metasys ventilation controller application for the dx9100 7 dx9100 the dx9100 is a controller manufactured and marketed by johnson controls. Dx91008454 version 2 dx912x8454 version 3 with mounting base the dx9100 processes the analog and digital input signals it receives, using 12 multipurpose programmable function modules, a softwareimplemented programmable logic controller plc, time schedule.
We pride ourselves on the quality of our repair service and understand the effect a faulty machine has on our customers production. This controller has a voltage of 24 vac and a frequency of 5060 hz. Download area download information on the full range of our products quickly and easily as pdf files. Metasys for validated environments, extended architecture is an offering from johnson controls for facilities that require regulatory compliance for their environmental systems. Increased reliability and resiliency with new network topology options. The metasys johnsoncontrols dx91008454 dx91008454 is an extended digital controller from the metasys dx series, version 2. Johnson controls dx91008454 metasys extended digital controller all of our items come only with what is pictured or described in the description. Includes gx9100 configuring and commissioning utilities for the dx9100. N2 was extended with the system91 protocol to support system91 devices like the dx9100. Browsing a qrcode its possible to display and manage the information coming directly from the different devices sunblinds, fun. If the fan status is not equal to the command within ten seconds of the command, the sonalert will sound. Mve brings the flexibility and convenience of a web interface to your regulated facility. Jci program software is needed to configure controller item was removed due to a control upgrade.
At johnson controls, our metasys building automation system is the foundation of modern building energy management efficiency. The scope of the installations is generally small so an investment in metasys is not warranted. Dx9100 extended digital controller technical bulletin. Free metasys launcher update download metasys launcher. The success of this product group can be attributed to the broad spectrum of efficacy, the pleasing and novel design as well as. Johnson controls metasys dx91008454 digital controller ebay. Jun 12, 2016 adding an additional analog output to a johnson controls dx 9100 requires program modification as well as hardware configuration of the system. Ryan has 10 years of experience in the controls industry and has held roles in software engineering and operations. Dx 9100 8454 by johnson controls buy or repair at radwell.
This is a johnson controls metasys dx 9100 84554 digital controller removed from working environment and in good working order. Related information document title code number fan dx9100 extended digital controller technical bulletin lit6364020 636. Johnson controls metasys dx 9100 controller dx 9100 8454 used but in great shape you are bidding on a johnson controls dx 9100 digital controller note. This allows your manufacturing facility to maintain your johnson controls metasys dx equipment with replacement controllers. The dx 9100 is still the best controller i have ever used. Bacnet field equipment controllers made for metasys at johnson controls, our building automation metasys fecs field equipment controllers feature 32bit microprocessors, patented continuous tuning adaptive control, peertopeer communications, and an optional builtin lcd screen user interface. N30 supervisory controller point mapping technical bulletin. View online or download metasys dt91008104 installation manual.
Jci programsoftware is needed to configure controller item was removed due to a control upgrade. The metasys ventilation controller application of the gx9100 software tool is used to program the dx9100. Metasys building automation and controls field device dx9100 dx9100 configuration guide lit6364030 6364030. Metasys network, companion, and facilitator supervisory systems. Adding an additional analog output to a johnson controls dx 9100 requires program modification as well as hardware configuration of the system. Johnson controls dx 9100 8454 automation parts warehouse. N2 was extended with the system91 protocol to support system91 devices like the dx 9100. Dx 91009120 applicationsdx 91009120 local sonalert logic 11 the timers allow the fan command to be on or off before the status is checked. N2 was again extended with the n2b variant to support vma devices. This utility supports converting the resource files for any n2 open, vma, or dx9100 device whose configuration utility is capable of creating. Metasys building automation and controls software application system configuration tool. The builtin help system guides you through the conversion process. Includes hvac pro configuring and commissioning utilities for the unt, ahu, vav, and vma metasys n2 open devices.
The dx 9100 is the ideal digital control solution for multiple chiller or. So here i am attempting to do a conversion from jci n2 to n4 on a jace8000 with a n2 driver. Johnson metasys dx91008454 digital hvac controller product details. I have a bias because we rep the johnson controls metasys product line. Dx91008454 by johnson controls buy or repair at radwell. View online or download metasys dt 9100 8104 installation manual. The metasys ventilation controller application of the gx 9100 software tool is used to program the dx 9100. Metasys software is a software service company that focus on dotnet, filemaker, ios, php and react based solutions.
1012 1118 1670 357 1031 392 1542 613 1406 487 1066 1203 1131 653 1361 213 1153 1559 243 334 1628 55 584 395 633 1410 1542 582 1614 1365 1305 554 64 761 1076 295 930 658